GTO/PRO
AC Operators are ETL listed to meet and exceed UL 325 Standards
All GTO/PRO AC operators include a special warning buzzer that is activated if the operator obstructs for a second time during any cycle. |
|||||||||||||||||||||||||||||||||||||||
Features | SL-5000 | SL-5100 | SL-6000 | SL-6100 | |||||||||||||||||||||||||||||||||||||
Maximum
Gate Size and Weights 1000 Lbs (453 kg) and 40ft (12.1 m) in length |
x | x | |||||||||||||||||||||||||||||||||||||||
2500
Lbs (1134 kg) and 50ft (15.1 m) in length
|
x | x | |||||||||||||||||||||||||||||||||||||||
Maximum
Gate Cycles: Continuous Duty.
|
x | x | x | x | |||||||||||||||||||||||||||||||||||||
GTO/Leeson
Motor: Custom made for GTO by Leeson Motors. 1625 RPM, total
enclosed, fan cooled, and thermally protected, with C-Face connections
and easily accessible reset button.
|
1/2HP | 1/2HP | 1 HP | 1 HP | |||||||||||||||||||||||||||||||||||||
Gear
Reducer: 30 to 1, 60 series reducer, with vertical type motor
flange. Totally enclosed with machine cut bronze gears in an oil
bath. Motor Mounts is a NEMA flange C-Face connection (eliminates need
for belts and pulleys)
|
x | x | x | x | |||||||||||||||||||||||||||||||||||||
GTO
Foot Release Pedal: GTO's unique, patent-pending safety feature
provides quick and easy (lockable) release for manual operation of gate.
|
x | x | x | x | |||||||||||||||||||||||||||||||||||||
Dimensions:
20" W c 22" D x 31" H (50cm x 55cm x 78cm)
|
x | x | x | x | |||||||||||||||||||||||||||||||||||||
Shipping
Weight:
|
166 lbs | 225 lbs. | 186 lbs | 225 lbs | |||||||||||||||||||||||||||||||||||||
Voltage:
110 volt @ 60 Hz
|
x | x | x | x | |||||||||||||||||||||||||||||||||||||
Control
Box: Patent-pending "pop-off" removable hinges allow
full and easy access. Box measures 16" H x 14" W x 6"D,
with a heavy duty steel backing. Holds the control boards, limit switches,
terminal blocks, etc. with ample room inside for additional accessories.
Constructed of fire retardant ABS plastic for resistance to corrosion
and weather.
|
x | x | x | x | |||||||||||||||||||||||||||||||||||||
Additional
AC Outlets: Two standard volt AC outlets under the control
box for additional accessories.
|
x | x | x | x | |||||||||||||||||||||||||||||||||||||
Chain: 20ft. of #40 chain with master link |
x | x | |||||||||||||||||||||||||||||||||||||||
20ft. of #50 chain with master link | x | x | |||||||||||||||||||||||||||||||||||||||
Guide Rollers: Made of highly durable UHMW plastic; provides extremely quiet operation. |
x | x | x | x | |||||||||||||||||||||||||||||||||||||
Housing: Paint able fiberglass housing is .200 thinck and mounted away from frame, to reduce chipping or cracking. Special U.V. treatment resists fading. Choice of black or white.
|
x |
x |
x |
x |
|||||||||||||||||||||||||||||||||||||
Radio
Controls: Standard GTO 318 MHz receiver and one transmitter
(included)
|
x |
x |
x |
x |
|||||||||||||||||||||||||||||||||||||
Heavy
Duty Steel Frame: Yellow Zinc plated for maximum corrosion
resistance.
|
x |
x |
x |
x |
|||||||||||||||||||||||||||||||||||||
Gate
Limit Settings: Mechanical limit switches are inside the control
box for maximum weather resistance and safety.
|
x |
x |
x |
x |
|||||||||||||||||||||||||||||||||||||
Mounting
Brackets: Included' can be welded or bolted on
|
x |
x |
x |
x |
|||||||||||||||||||||||||||||||||||||
Warranty: Residential 5 year on mechanical systems, 3 years on electronics. Commercial; 3 years on mechanical systems, 2 years on electronics.
|
x |
x |
x |
x |
|||||||||||||||||||||||||||||||||||||
Adjustable
Auto Close and Obstruction Sensing:
Automatically reverses in either direction
|
x |
x |
x |
x |
|||||||||||||||||||||||||||||||||||||
Diagnostics:
LED next to each terminal provides easy diagnostics
|
x |
x |
x |
x |
|||||||||||||||||||||||||||||||||||||
Potentiometers
& Switches: Provides easy adjustment on the control board.
|
x |
x |
x |
x |
|||||||||||||||||||||||||||||||||||||
Built-In
24 Volt DC Transformer: Makes operators add-on-ready for any
number of N/O or N/C accessories and options (up to 0.5 amp draw
|
x |
x |
x |
x |
|||||||||||||||||||||||||||||||||||||
Terminals
for Safety Edges: 6 provided.
|
x |
x |
x |
x |
|||||||||||||||||||||||||||||||||||||
Dual
Gate Port: Automatically recognizes gate sequencing options
when programmed.
|
x ` |
x |
x |
x |
|||||||||||||||||||||||||||||||||||||
Soft
Start/soft Stop
|
x |
x |
|||||||||||||||||||||||||||||||||||||||
Battery
Backup: Provides up to 50 cycles without power.
|
x |
x |
|||||||||||||||||||||||||||||||||||||||
Additional
Terminal Connections: Provide connections for modem and LCD.
|
x |
x |
|||||||||||||||||||||||||||||||||||||||
Auxiliary
Output Relays: Triggers other devices such as 2-stage security
gates, remote mounted
|
x |
x |
|||||||||||||||||||||||||||||||||||||||
PC Port: For on-site monitoring |
x |
x |
|||||||||||||||||||||||||||||||||||||||
|
|
||||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||||
Another